Air velocity transmitter

View:

eYc FTM84/85 Industrial grade high accuracy thermo air velocity transmitter

Features :
Sensor Type : Thermal mass flow sensor
Air Velocity Measuring Range : 1 ... 120m/
Air Velocity min. Measuring Range : 0.15 m/s
Temp. Sensor / Measuring Range : PT 1000, 0 ... 80 ℃
Accuracy ( + 25 °C ) : Air velocity : ± 1.5 % F.S.
Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC
Display : Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc FTM06 Hot wire thermal air velocity transmitter

Feature : Micro-corrosion air measurement. Strong housing with analog and RS-485 output.
Type : Resistance Temperature Detector
Range : Air : 0 ... 60 m/s
Output Signal : Analog : 4 ... 20mA / 0 ... 10V ; RS-485
Product Accuracy : Air(at 25°C) :3% < 60 m/s
Power Supply : 8 ... 35 VDC
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS34/35 Air Velocity Transmitter

Features :
Sensor type : Thermal mass flow sensor
Air velocity measuring range : 2 m/s ; 10 m/s;20 m/s;40 m/s
Air velocity min. measuring range : 0.2 m/s
Accuracy( +25°C ) : air velocity : ± 2 % F.S.
Output : 4 ... 20 mA / 0 ... 10 VDC
Display:Optional
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc AFMT Average Flow Measuring Tube ( Pitot tube )

Duct-mounting type/Material: stainless 316
Operating temperature:max. 250°C
Length(L)/mm:4" ... 40"
Option:differencial pressure trainsmitter(can measure flow)
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(Leb number: 3032)

eYc FTS14 Air Velocity Transmitter

Output : 4 ... 20 mA / 0 ... 10 VDC
Air velocity measuring range : 20 m/s
Accuracy( +25°C ) : ± 5 % F.S. ( nonlinear error, hysteresis error,repeatability error )
Thermal sensitivity temp. error : 0.2 % / °C
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc AFMS-160 S-type Pitot tube

Feature : High temperature resistance, Corrosion resistant, Anti-clogging, Data convert to flow rate quickly
Operating pressure : Max 10 bar
Operating temperature : Max. 250 °C ; Temperature tolerance : 800°C
Measuring medium / coefficient : Air / flow coefficient 0.84
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)

eYc FTS07 Hot wire air velocity transmitter

Probe type、2-meter cable、Highly stability and repeatability
10m/s;20m/s ; 0 ... 10VDC
●Additional option (ILAC/TAF) Test report - Standard Calibration laboratory(TAF Accreditation: 3032)